| Residential Walkways | Bollard, path light, or low-level post fixture | 0.5–2 footcandles 5–20 lux | 300–800 lumens | 2700–3000 K | Wide, shielded distribution with low glare | Astronomical timer, photocell, or occupancy sensor | Use even spacing and keep light directed toward the walking surface. |
| Residential Steps | Step light, recessed wall light, or surface-mounted fixture | 1–3 footcandles 10–30 lux | 100–500 lumens | 2700–3000 K | Shielded downward light; avoid direct views of the LED source | Photocell with time-based dimming | Provide consistent illumination on treads, risers, and landings. |
| Driveways and Small Parking Areas | Area light, wall pack, or pole-mounted LED fixture | 0.5–2 footcandles 5–20 lux | 2,000–8,000 lumens | 3000–4000 K | Full-cutoff optics to limit spill light and glare | Photocell, schedule, and occupancy-based dimming | Confirm mounting height, uniformity, and property-line light trespass. |
| Commercial Parking Areas | Pole-mounted area or shoebox fixture | 0.5–3 footcandles 5–30 lux | 8,000–30,000 lumens | 3000–4000 K | Asymmetric distribution selected by pole layout | Photocell, astronomical timeclock, and scheduled dimming | Design for target average illumination, uniformity, glare control, and local codes. |
| Building Entrances | Canopy light, wall sconce, or downlight | 2–5 footcandles 20–50 lux | 1,000–5,000 lumens | 3000–4000 K | Downward or shielded distribution focused on doors and signage | Occupancy sensor with high-low dimming and after-hours schedule | Avoid excessive contrast between the entrance, surrounding path, and interior lobby. |
| Security Perimeters | Full-cutoff floodlight or wall-mounted area light | 1–3 footcandles 10–30 lux | 2,000–12,000 lumens | 3000–4000 K | Controlled beam aimed across the monitored zone, not toward observers | Motion sensor, photocell, and adjustable time delay | Prioritize uniform coverage, camera compatibility, and minimal spill into neighboring properties. |
| Landscape and Trees | Well light, adjustable spotlight, or in-ground uplight | Accent lighting; generally lower than circulation lighting | 200–1,500 lumens | 2700–3000 K | Narrow or adjustable beam aimed at trunks, foliage, or architectural features | Astronomical timer with late-night dimming or shutoff | Use glare shields, avoid aiming into windows, and protect vegetation from excessive heat. |
| Outdoor Signage | Sign light, linear graze light, or adjustable floodlight | Based on sign contrast and applicable sign regulations | 500–5,000 lumens | 3000–4000 K | Uniform wall-wash or grazing distribution with concealed sources | Photocell and curfew schedule | Check sign brightness limits, viewing angles, and local ordinances before installation. |
| Wet or Coastal Locations | Sealed exterior fixture rated for the installation environment | Select according to the task area | 300–10,000 lumens | 2700–4000 K | Optics matched to the task, with sealed lenses and appropriate shielding | Photocell, timer, and occupancy control where suitable | Verify the required wet-location rating, corrosion resistance, drainage, and cable-entry protection. |